What Is RAID?

RAID (Redundant Array of Independent Disks) is a storage technology that combines multiple physical drives into a logical storage array. Depending on the RAID level, data can be striped, mirrored, or protected with parity to improve performance, redundancy, storage capacity, or fault tolerance.

RAID is widely used in servers and data centers where a drive failure should not necessarily make stored data unavailable. Different RAID levels provide different trade-offs between usable capacity, performance, and protection against drive failures.

RAID is not a backup solution. It can protect against certain hardware failures, but it does not provide a separate copy of data that can be restored after accidental deletion, corruption, ransomware, or other forms of data loss.

Key Takeaways

  • RAID combines multiple physical drives into a logical storage array.
  • RAID levels use different combinations of striping, mirroring, and parity.
  • RAID 0 prioritizes performance and capacity but provides no redundancy.
  • RAID 1 mirrors data between drives for redundancy.
  • RAID 5 uses distributed parity and can tolerate one drive failure.
  • RAID 6 uses dual parity and can tolerate two drive failures.
  • RAID 10 combines mirroring and striping for performance and redundancy.
  • RAID should normally be combined with a separate backup strategy.

How Does RAID Work?

RAID manages multiple physical drives as a coordinated storage array. The way data is distributed across those drives depends on the selected RAID level.

Three basic techniques form the foundation of most RAID configurations.

Striping

Striping divides data into blocks and distributes those blocks across multiple drives.

Because several drives can participate in I/O operations, striping can improve storage performance. However, striping alone provides no redundancy.

RAID 0 uses striping without mirroring or parity. If one drive fails, data stored across the array may become inaccessible.

Mirroring

Mirroring writes the same data to multiple drives.

If one drive fails, another drive can retain a copy of the data. RAID 1 uses this approach, while RAID 10 combines mirrored drives with striping.

The main trade-off is usable capacity because part of the raw storage is used to maintain duplicate data.

Parity

Parity stores additional information that allows missing data to be reconstructed after certain drive failures.

RAID 5 distributes parity across the array and can recover from the failure of one drive. RAID 6 stores two sets of parity and can tolerate the failure of two drives.

Parity provides redundancy without requiring a complete copy of all data, but it introduces additional processing and storage overhead.

What Are the Main RAID Levels?

There is no universally best RAID level. Each configuration makes a different trade-off between performance, usable capacity, and fault tolerance.

RAID levelMain techniqueDrive failure toleranceTypical characteristic
RAID 0StripingNoneHigh performance and capacity, no redundancy
RAID 1MirroringOne drive in a mirrored pairSimple redundancy, lower usable capacity
RAID 5Striping + distributed parityOne driveBalance of capacity and redundancy
RAID 6Striping + dual parityTwo drivesHigher fault tolerance
RAID 10Mirroring + stripingDepends on failed drivesHigh performance with redundancy

RAID 0: Performance Without Redundancy

RAID 0 distributes data across multiple drives without maintaining redundant copies or parity.

Its main advantage is performance: multiple drives can process storage operations in parallel, and the array can use the combined capacity of its member drives.

The trade-off is that RAID 0 provides no fault tolerance. If one drive fails, the entire array can become unusable and data may be lost.

RAID 0 is therefore appropriate only when the data can be recreated or recovered from another source.

RAID 1: Mirrored Storage

RAID 1 creates an identical copy of data on another drive.

If one drive fails, the mirrored drive can continue providing access to the data. This makes RAID 1 straightforward to manage and useful when redundancy is more important than maximizing storage capacity.

The main limitation is capacity efficiency. In a typical two-drive RAID 1 configuration, roughly half of the raw capacity is available for the primary data because the other half is used for the mirror.

RAID 5: Capacity With Single-Drive Fault Tolerance

RAID 5 combines striping with distributed parity.

The parity information allows the array to reconstruct data after the failure of one drive. Compared with RAID 1, RAID 5 can provide more usable capacity because it does not maintain a complete mirrored copy of the dataset.

The trade-off is parity overhead, particularly for write operations. RAID 5 can therefore be useful when an environment needs a balance between capacity, performance, and protection against a single drive failure.

RAID 6: Protection Against Two Drive Failures

RAID 6 works similarly to RAID 5 but maintains two sets of distributed parity.

This allows the array to remain operational after the failure of two drives. The additional protection comes with more parity overhead and lower usable capacity than an equivalent RAID 5 configuration.

RAID 6 can be particularly useful for larger storage arrays where additional fault tolerance is important.

RAID 10: Performance and Redundancy

RAID 10 combines mirroring and striping. Data is mirrored between drive pairs and striped across those mirrored sets.

This provides both redundancy and parallel I/O performance. In a standard mirrored-pair configuration, RAID 10 can tolerate multiple drive failures as long as at least one drive in each mirrored pair remains operational. If both drives in the same mirrored pair fail, the array loses access to that mirrored data.

The main disadvantage is capacity efficiency: approximately half of the raw capacity is used for mirrored copies.

Hardware RAID vs Software RAID

RAID can be implemented through dedicated hardware or managed by the operating system.

Hardware RAID uses a dedicated RAID controller to manage the storage array. The controller handles RAID operations independently of the operating system.

Software RAID is managed by the operating system. It can provide RAID functionality without requiring a dedicated hardware controller.

Neither approach is universally better. The choice depends on the server architecture, operating system, workload, performance requirements, and management model.

XLC supports both HardRAID and SoftRAID configurations, allowing the RAID implementation to be selected according to storage requirements.

RAID With HDD and SSD Storage

RAID can be implemented with both HDDs and SSDs, but the choice of drive technology affects the performance and economics of the array.

HDD-based RAID is generally suitable when high capacity and cost per terabyte are priorities. This makes it useful for many backup, archive, and bulk-storage workloads.

SSD-based RAID provides lower storage latency and higher I/O performance, making it more appropriate for active datasets, databases, and workloads with demanding storage access patterns.

The RAID level and drive type should therefore be considered together. A RAID configuration cannot compensate for the fundamental performance characteristics of the underlying storage technology.

Does RAID Replace Backup?

No. RAID and backup solve different problems.

RAID is designed to maintain storage availability and protect against certain physical drive failures.

A backup provides a separate copy of data that can be restored after events such as:

  • accidental deletion;
  • file corruption;
  • ransomware;
  • application errors;
  • configuration mistakes;
  • hardware failures affecting the entire storage system.

For example, if a file is accidentally deleted, RAID will normally replicate that deletion across the redundant copies. A backup can provide an earlier version of the file instead.

A resilient storage architecture can therefore combine RAID for hardware fault tolerance with backups for data recovery.

XLC’s backup storage is designed for backup, disaster recovery, archival retention, and long-term data protection.

How Does RAID Affect Usable Storage Capacity?

The amount of usable storage depends on the RAID level rather than simply adding together the capacity of every physical drive.

For example:

  • RAID 0 can use the combined capacity of the array, subject to the configuration and drive sizes.
  • RAID 1 uses mirrored copies, reducing usable capacity.
  • RAID 5 uses the equivalent of one drive’s capacity for distributed parity.
  • RAID 6 uses the equivalent of two drives’ capacity for dual parity.
  • RAID 10 uses mirrored copies, so approximately half of the raw capacity is available for primary data.

Actual usable capacity can also be affected by drive sizes, filesystem overhead, hot spares, and the specific storage implementation.

For this reason, storage requirements should always be calculated using usable RAID capacity, not the sum of the advertised capacities of the individual drives.

How Do You Choose the Right RAID Level?

The right RAID level depends on the workload and the balance required between performance, capacity, and fault tolerance.

Consider Fault Tolerance

First determine how many drive failures the system should tolerate.

RAID 1 and RAID 5 can protect against a single drive failure in their typical configurations, while RAID 6 is designed to tolerate two drive failures.

RAID 10 provides redundancy through mirrored drive pairs, with its failure tolerance depending on which drives fail.

Consider Performance

Look at the workload’s read and write patterns.

High-I/O workloads may benefit from RAID 10, while capacity-focused environments may prefer parity-based RAID configurations.

Consider Usable Capacity

More redundancy usually means less usable capacity.

Compare the amount of data that needs to be stored with the capacity available after applying the selected RAID layout.

Consider Drive Type

HDDs, SSDs, and hybrid storage configurations have different cost and performance characteristics. The RAID design should match the underlying drives and the workload.

Consider Recovery Requirements

Think about what happens after a drive failure, including rebuild time and the possibility of another failure during the recovery process.

For larger storage environments, fault tolerance and recovery planning become increasingly important.

XLC also offers custom storage configurations where high-capacity drives and advanced RAID levels can be configured around the required balance of space, performance, and redundancy.

When comparing configurations, storage server pricing can also help evaluate the overall cost of different capacity and redundancy options.

RAID in Server Storage Infrastructure

RAID is widely used in dedicated storage servers where large amounts of data need to remain available despite individual drive failures.

A typical infrastructure may combine:

Application servers → Database servers → Storage servers → Backup storage

In this setup, RAID helps protect the storage layer against certain drive failures, while separate backup infrastructure provides recoverability when data is deleted, corrupted, or otherwise compromised.

RAID can therefore contribute to availability and hardware resilience, but it should not be treated as the complete data protection strategy.

Frequently Asked Questions

RAID is a storage technology that combines multiple physical drives into a logical array. Different RAID levels use striping, mirroring, or parity to balance performance, capacity, and protection against drive failures.

There is no universally best RAID level. RAID 0 prioritizes performance without redundancy, RAID 1 provides mirroring, RAID 5 and RAID 6 use parity for fault tolerance, and RAID 10 combines mirroring with striping.

RAID 0 provides no redundancy. If one drive fails, the array can become inaccessible and data may be lost. It should only be used when the data can be recreated or recovered from another source.

RAID 5 can be suitable when a workload needs a balance of usable capacity, performance, and protection against one drive failure. The appropriate configuration depends on the workload and recovery requirements.

RAID protects against certain hardware failures, particularly drive failures, depending on the RAID level. It does not protect against every form of data loss, including accidental deletion, corruption, or ransomware.

Hardware RAID uses a dedicated controller to manage the array, while software RAID is managed by the operating system. The appropriate option depends on the server architecture and workload.

No. RAID provides redundancy and availability against certain hardware failures, while a backup provides a separate copy that can be restored after data loss.

確実なサポートで、確実なソリューションを。

超低遅延、グローバルな到達範囲、高セキュリティ。